Pan-European infrastructure for ocean & marine data management

P01 Vocabulary - Facet Search on Semantic Components

P01 Vocabulary - Facet Search on Semantic Components

The P01 Parameter Usage Vocabulary is based on a semantic model. This model uses a defined set of controlled vocabularies (the semantic components). The Facet Search below facilitates you to search for specific existing P01 terms using components for drilling down.

Are you missing specific P01 terms in the vocabulary, then you can compose and submit new terms for review and uptake using the P01 Vocabulary Builder tool.

Conceptid (12)Preflabel
AMONASSDUptake rate standard deviation of ammonium {NH4+ CAS 14798-03-9} {regenerated production standard deviation} per hour per unit volume of the water body [particulate >GF/F phase] by isotope-labelled tracer addition, in-situ incubation, filtration and mass spectrometry on residue
NAUEROP1Uptake rate standard error of ammonium {NH4+ CAS 14798-03-9} per hour per unit volume of the water body [particulate >GF/F phase] by isotope-labelled tracer addition, on-deck incubation at simulated in-situ light level, filtration and mass spectrometry on residue
NAUPIS01Uptake rate of ammonium {NH4+ CAS 14798-03-9} per hour per unit volume of the water body [particulate GF/F-2um phase] by isotope-labelled tracer addition, in-situ incubation, cascade filtration and mass spectrometry on residue
NAUPRAP1Uptake rate of ammonium {NH4+ CAS 14798-03-9} per hour per unit volume of the water body [particulate >GF/F phase] by tracer doping, incubation at 100uE/m2/s light level, filtration and mass spectrometry on residue
NAUPRBP1Uptake rate of ammonium {NH4+ CAS 14798-03-9} per hour per unit volume of the water body [particulate >GF/F phase] by tracer doping, incubation at 188uE/m2/s light level, filtration and mass spectrometry on residue
NAUPRDP1Uptake rate of ammonium {NH4+ CAS 14798-03-9} per hour per unit volume of the water body [particulate >GF/F phase] by isotope-labelled tracer addition, incubation in the dark, filtration and mass spectrometry on residue
NAUPROP1Uptake rate of ammonium {NH4+ CAS 14798-03-9} per hour per unit volume of the water body [particulate >GF/F phase] by isotope-labelled tracer addition, on-deck incubation at simulated in-situ light level, filtration and mass spectrometry on residue
NAUPRSD1Uptake rate standard deviation of ammonium {NH4+ CAS 14798-03-9} per hour per unit volume of the water body [particulate >GF/F phase] by isotope-labelled tracer addition, on-deck incubation at simulated in-situ light level, filtration and mass spectrometry on residue
NAUPRSP1Uptake rate of ammonium {NH4+ CAS 14798-03-9} per hour per unit volume of the water body [particulate >GF/F phase] by tracer doping, on-deck incubation at full natural light level, filtration and mass spectrometry on residue
NH4UPT01Uptake rate of ammonium {NH4+ CAS 14798-03-9} per hour per unit volume of the water body [particulate >GF/F phase] by isotope-labelled tracer addition, in-situ incubation, filtration and mass spectrometry on residue
NUUPRBP1Uptake rate of urea {CAS 57-13-6} per hour per unit volume of the water body [particulate >GF/F phase] by tracer doping, incubation at 188uE/m2/s light level, filtration and mass spectrometry on residue
SNAURSPMUptake rate of ammonium {NH4+ CAS 14798-03-9} per hour per unit volume of the water body [particulate GF/F-5um phase] by tracer doping, on-deck incubation at full natural light level, cascade filtration and mass spectrometry on residue