Pan-European infrastructure for ocean & marine data management

P01 Vocabulary - Facet Search on Semantic Components

P01 Vocabulary - Facet Search on Semantic Components

The P01 Parameter Usage Vocabulary is based on a semantic model. This model uses a defined set of controlled vocabularies (the semantic components). The Facet Search below facilitates you to search for specific existing P01 terms using components for drilling down.

Are you missing specific P01 terms in the vocabulary, then you can compose and submit new terms for review and uptake using the P01 Vocabulary Builder tool.

Conceptid (94)Preflabel
ACIDAE01Concentration of iodide {I- CAS 20461-54-5} per unit volume of the atmosphere [aerosol <1um phase] by filtration and cathodic stripping voltammetry
ACIDAE02Concentration of iodide {I- CAS 20461-54-5} per unit volume of the atmosphere [aerosol >1um phase] by filtration and cathodic stripping voltammetry
ACIDXX01Concentration of iodide {I- CAS 20461-54-5} per unit volume of the atmosphere [aerosol phase] by filtration and cathodic stripping voltammetry
ASDIDA01Concentration standard deviation of iodide {I- CAS 20461-54-5} per unit volume of the atmosphere [aerosol <1um phase] by filtration and cathodic stripping voltammetry
ASDIDA02Concentration standard deviation of iodide {I- CAS 20461-54-5} per unit volume of the atmosphere [aerosol >1um phase] by filtration and cathodic stripping voltammetry
ASDIDX01Concentration standard deviation of iodide {I- CAS 20461-54-5} per unit volume of the atmosphere [aerosol phase] by filtration and cathodic stripping voltammetry
CDXXCVDXConcentration of cadmium {Cd CAS 7440-43-9} per unit volume of the water body [dissolved plus reactive particulate phase] by UV digestion and cathodic stripping voltammetry
CO02CSVXConcentration of cobalt {Co CAS 7440-48-4} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, UV digestion and cathodic stripping voltammetry
COCSV04XConcentration of cobalt {Co CAS 7440-48-4} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, UV digestion and cathodic stripping voltammetry
COL02CSVConcentration of labile cobalt {labile_Co CAS 7440-48-4} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, UV digestion and cathodic stripping voltammetry
COLCSV04Concentration of labile cobalt {labile_Co CAS 7440-48-4} per unit volume of the water body [dissolved plus reactive particulate <0.4/0.45um phase] by filtration, UV digestion and cathodic stripping voltammetry
COLGCVDXConcentration of organic ligand-bound cobalt {ligand-complexed_Co CAS 7440-48-4} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry
COLGCVZZLog ligand binding strength of cobalt-complexing organic ligands {Co_org_ligands} in the water body [dissolved plus reactive particulate <0.2um phase] by filtration and cathodic stripping voltammetry
COXXCVDXConcentration of cobalt {Co CAS 7440-48-4} per unit volume of the water body [dissolved plus reactive particulate phase] by UV digestion and cathodic stripping voltammetry
CRXXCVDXConcentration of chromium {Cr CAS 7440-47-3} per unit volume of the water body [dissolved plus reactive particulate phase] by UV digestion and cathodic stripping voltammetry
CTM00110Concentration of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry
CTM00220Concentration standard error of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry
CTM00660Concentration of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry
CTM00770Concentration standard error of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry
CTM01111Concentration of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry
CTM01212Concentration standard error of iron-complexing organic ligands {Fe_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.2 and cathodic stripping voltammetry
CTM01616Concentration of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry
CTM01717Concentration standard error of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 8.05 and cathodic stripping voltammetry
CTM02121Concentration of copper-complexing organic ligands {Cu_org_ligands} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, pH adjusted to 7.6 and cathodic stripping voltammetry