Export OF P01 One armed bandit search "Conceptid (P01)","Preflabel (P01)","Conceptid (P02)","Preflabel (P02)" "ALSDFIP5","Concentration standard deviation of aluminium {Al CAS 7429-90-5} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, in-line preconcentration and flow-injection fluorometry","MTWD","Dissolved metal concentrations in the water column" "ALSDLG01","Concentration standard deviation of aluminium {Al CAS 7429-90-5} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and lumogallion fluorescence","MTWD","Dissolved metal concentrations in the water column" "CDCOICSD","Concentration standard deviation of cobalt {Co CAS 7440-48-4} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry","MTWD","Dissolved metal concentrations in the water column" "CDNIICSD","Concentration standard deviation of nickel {Ni CAS 7440-02-0} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry","MTWD","Dissolved metal concentrations in the water column" "CDSDKGI5","Concentration standard deviation of cadmium {Cd CAS 7440-43-9} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry","MTWD","Dissolved metal concentrations in the water column" "CDVOLDMT","Concentration standard deviation of cadmium {Cd CAS 7440-43-9} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry","MTWD","Dissolved metal concentrations in the water column" "COICPMSD","Concentration standard deviation of cobalt {Co CAS 7440-48-4} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry","MTWD","Dissolved metal concentrations in the water column" "COSDCLD5","Concentration standard deviation of cobalt {Co CAS 7440-48-4} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification, UV irradiation and flow-injection chemiluminescence","MTWD","Dissolved metal concentrations in the water column" "CTITI002","Concentration standard deviation of titanium {Ti CAS 7440-32-6} in the water body [dissolved plus reactive particulate <0.2um phase]","MTWD","Dissolved metal concentrations in the water column" "CUSDASV1","Concentration standard deviation of copper {Cu CAS 7440-50-8} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and anodic stripping voltammetry","MTWD","Dissolved metal concentrations in the water column" "CUSDKGI5","Concentration standard deviation of copper {Cu CAS 7440-50-8} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry","MTWD","Dissolved metal concentrations in the water column" "CUVOLDMT","Concentration standard deviation of copper {Cu CAS 7440-50-8} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry","MTWD","Dissolved metal concentrations in the water column" "CZI87002","Concentration standard deviation of zinc {Zn CAS 7440-66-6} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and flow-injection fluorometry","MTWD","Dissolved metal concentrations in the water column" "DFEFICSD","Concentration standard deviation of total iron {total_Fe CAS 7439-89-6} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and flow-injection chemiluminescence","MTWD","Dissolved metal concentrations in the water column" "FE2FICSD","Concentration standard deviation of ferrous ion {Fe2+ divalent iron CAS 15438-31-0} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and flow-injection chemiluminescence","MTWD","Dissolved metal concentrations in the water column" "FEFICKG3","Concentration standard deviation of total iron {total_Fe CAS 7439-89-6} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and flow-injection chemiluminescence","MTWD","Dissolved metal concentrations in the water column" "FESDKGI5","Concentration standard deviation of total iron {total_Fe CAS 7439-89-6} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry","MTWD","Dissolved metal concentrations in the water column" "FESDKGI6","Concentration standard deviation of total iron {total_Fe CAS 7439-89-6} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry","MTWD","Dissolved metal concentrations in the water column" "GASDICP6","Concentration standard deviation of gallium {Ga CAS 7440-55-3} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry","MTWD","Dissolved metal concentrations in the water column" "LASDKGI5","Concentration standard deviation of lanthanum {La CAS 7439-91-0} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry","MTWD","Dissolved metal concentrations in the water column" "MNSDFID1","Concentration standard deviation of total manganese {total_Mn CAS 7439-96-5} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration and flow-injection chemiluminescence","MTWD","Dissolved metal concentrations in the water column" "MNSDKGI5","Concentration standard deviation of total manganese {total_Mn CAS 7439-96-5} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry","MTWD","Dissolved metal concentrations in the water column" "MNVOLDMT","Concentration standard deviation of total manganese {total_Mn CAS 7439-96-5} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry","MTWD","Dissolved metal concentrations in the water column" "NISDKGI5","Concentration standard deviation of nickel {Ni CAS 7440-02-0} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry","MTWD","Dissolved metal concentrations in the water column" "PBSDICP6","Concentration standard deviation of lead {Pb CAS 7439-92-1} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry","MTWD","Dissolved metal concentrations in the water column" "PBVOLDSD","Concentration standard deviation of lead {Pb CAS 7439-92-1} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry","MTWD","Dissolved metal concentrations in the water column" "VB341GM1","Concentration standard deviation of barium {Ba CAS 7440-39-3} per unit volume of water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry","MTWD","Dissolved metal concentrations in the water column" "YSDKGIC5","Concentration standard deviation of yttrium {Y CAS 7440-65-5} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry","MTWD","Dissolved metal concentrations in the water column" "ZN02SDF1","Concentration standard deviation of zinc {Zn CAS 7440-66-6} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and flow-injection fluorometry","MTWD","Dissolved metal concentrations in the water column" "ZNCOICP6","Concentration standard deviation of zinc {Zn CAS 7440-66-6} per unit volume of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry","MTWD","Dissolved metal concentrations in the water column" "ZNSDKGI5","Concentration standard deviation of zinc {Zn CAS 7440-66-6} per unit mass of the water body [dissolved plus reactive particulate <0.2um phase] by filtration, acidification and inductively-coupled plasma mass spectrometry","MTWD","Dissolved metal concentrations in the water column"